<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-21 20-34-41
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 51 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 69 kHz 12460 3,5634
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,7 dBr 5,00 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 69 kHz MIN: 13 kHz % above 76 kHz: 3,5634 Acquired: 2025/07/21 20.33.38 Total samples: 12460 Equivalent time: 0:10:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 6,2 dBr MIN: 2,7 dBr AVE: 5,00 dBr % above 12,2 dBr: 0,0 Last value: 5,6 dBr (2025/07/21 20.33.38) 20.20 20.22 20.24 20.26 20.28 20.30 20.32 0 2 4 6 Pm [dBr]